TOOLS

roots booster pumps

50 models in this family, 429 published parameters, each carrying the source key and the page it was read on.

Back to the selector, which answers across all 333 models and 14 families.

RUVAC RA 130003611 l/sNominal displacement speed, down to 5.0e-2 mbardrypump-leybold-ruvac-ra+8 parameters

Leybold, roots booster.

ambient temp range12 - 40 °Cdrypump-leybold-ruvac-ra

Read on drypump-leybold-ruvac-ra.

differential pressure max53 mbardrypump-leybold-ruvac-ra

Read on drypump-leybold-ruvac-ra.

inlet flangeDN 300drypump-leybold-ruvac-ra

Read on drypump-leybold-ruvac-ra.

noise level72 dB (A)drypump-leybold-ruvac-ra

Read on drypump-leybold-ruvac-ra.

Read on drypump-leybold-ruvac-ra.

pumping speed nominal13000 m3 · h-1drypump-leybold-ruvac-ra

Read on drypump-leybold-ruvac-ra. Served to the builder as 3611 l/s, read from 13000 m3 · h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

service interval3,000 hours of operationdrypump-leybold-ruvac-ra

Read on drypump-leybold-ruvac-ra.

ultimate pressurestated as a bound< 5 x 10-2 mbardrypump-leybold-ruvac

Read on drypump-leybold-ruvac.

RUVAC RA 90012700 l/sNominal displacement speed, down to 5.0e-2 mbardrypump-leybold-ruvac-ra+10 parameters

Leybold, roots booster.

ambient temp range12 - 40 °Cdrypump-leybold-ruvac-ra

Read on drypump-leybold-ruvac-ra.

backing pump min speed3240 m3/h (1907 cfm)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

differential pressure max66 mbardrypump-leybold-ruvac-ra

Read on drypump-leybold-ruvac-ra.

inlet flangeDN 300drypump-leybold-ruvac-ra

Read on drypump-leybold-ruvac-ra.

Read on drypump-leybold-ruvac-ra.

noise level69 dB (A)drypump-leybold-ruvac-ra

Read on drypump-leybold-ruvac-ra.

Read on drypump-leybold-ruvac-ra.

pumping speed nominal9720 m3 · h-1drypump-leybold-ruvac-ra

Read on drypump-leybold-ruvac-ra. Served to the builder as 2700 l/s, read from 9720 m3 · h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

service interval3,000 hours of operationdrypump-leybold-ruvac-ra

Read on drypump-leybold-ruvac-ra.

ultimate pressurestated as a bound< 5 x 10-2 mbardrypump-leybold-ruvac

Read on drypump-leybold-ruvac.

RUVAC RA 70012075 l/sNominal displacement speed, down to 4.0e-2 mbardrypump-leybold-ruvac-ra+10 parameters

Leybold, roots booster.

ambient temp range12 - 40 °Cdrypump-leybold-ruvac-ra

Read on drypump-leybold-ruvac-ra.

backing pump min speed1250 m3/h (0736 cfm)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

differential pressure max53 mbardrypump-leybold-ruvac-ra

Read on drypump-leybold-ruvac-ra.

inlet flangeDN 250drypump-leybold-ruvac-ra

Read on drypump-leybold-ruvac-ra.

Read on drypump-leybold-ruvac-ra.

noise level79 dB (A)drypump-leybold-ruvac-ra

Read on drypump-leybold-ruvac-ra.

power max18,5 kWdrypump-leybold-ruvac-ra

Read on drypump-leybold-ruvac-ra.

pumping speed nominal7470 m3 · h-1drypump-leybold-ruvac-ra

Read on drypump-leybold-ruvac-ra. Served to the builder as 2075 l/s, read from 7470 m3 · h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

service interval3,000 hours of operationdrypump-leybold-ruvac-ra

Read on drypump-leybold-ruvac-ra.

ultimate pressurestated as a bound< 4 x 10-2 mbardrypump-leybold-ruvac

Read on drypump-leybold-ruvac.

RUVAC WH 70001944 l/sNominal displacement speeddrypump-leybold-ruvac+9 parameters

Leybold, roots booster.

ambient temp range+12 to +40 (+54 to +104) °C (°F)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

backing pump min speed1400 m3/h (0824 cfm)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

Read on drypump-leybold-ruvac-whu.

differential pressure max20 to 30 mbardrypump-leybold-ruvac

Read on drypump-leybold-ruvac.

inlet flange320 ISO-Kdrypump-leybold-ruvac-whu

Read on drypump-leybold-ruvac-whu.

mass650 (1433) kg (lbs)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

noise level< 63 dB(A)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

pumping speed nominal7000 (4123) m3 x h-1 (cfm)drypump-leybold-ruvac

Read on drypump-leybold-ruvac. Served to the builder as 1944 l/s, read from 7000 m3 x h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

service intervalOil change for LVO 210 1 yeardrypump-leybold-ruvac-whu

Read on drypump-leybold-ruvac-whu.

RUVAC WHU 70001944 l/sNominal displacement speeddrypump-leybold-ruvac+9 parameters

Leybold, roots booster.

ambient temp range+12 to +40 (+54 to +104) °C (°F)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

backing pump min speed1400 m3/h (0824 cfm)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

Read on drypump-leybold-ruvac-whu.

differential pressure max70 mbardrypump-leybold-ruvac-whu

Read on drypump-leybold-ruvac-whu.

inlet flange320 ISO-Kdrypump-leybold-ruvac-whu

Read on drypump-leybold-ruvac-whu.

mass650 (1433) kg (lbs)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

noise level< 63 dB(A)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

pumping speed nominal7000 (4123) m3 x h-1 (cfm)drypump-leybold-ruvac

Read on drypump-leybold-ruvac. Served to the builder as 1944 l/s, read from 7000 m3 x h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

service intervalOil change for LVO 210 1 yeardrypump-leybold-ruvac-whu

Read on drypump-leybold-ruvac-whu.

RUVAC RA 50011542 l/sNominal displacement speed, down to 4.0e-2 mbardrypump-leybold-ruvac-ra+10 parameters

Leybold, roots booster.

ambient temp range12 - 40 °Cdrypump-leybold-ruvac-ra

Read on drypump-leybold-ruvac-ra.

backing pump min speed0930 m3/h (0547 cfm)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

differential pressure max53 mbardrypump-leybold-ruvac-ra

Read on drypump-leybold-ruvac-ra.

inlet flangeDN 200drypump-leybold-ruvac-ra

Read on drypump-leybold-ruvac-ra.

Read on drypump-leybold-ruvac-ra.

noise level78 dB (A)drypump-leybold-ruvac-ra

Read on drypump-leybold-ruvac-ra.

Read on drypump-leybold-ruvac-ra.

pumping speed nominal5550 m3 · h-1drypump-leybold-ruvac-ra

Read on drypump-leybold-ruvac-ra. Served to the builder as 1542 l/s, read from 5550 m3 · h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

service interval3,000 hours of operationdrypump-leybold-ruvac-ra

Read on drypump-leybold-ruvac-ra.

ultimate pressurestated as a bound< 4 x 10-2 mbardrypump-leybold-ruvac

Read on drypump-leybold-ruvac.

RUVAC WH 44001222 l/sNominal displacement speeddrypump-leybold-ruvac+9 parameters

Leybold, roots booster.

ambient temp range+12 to +40 (+54 to +104) °C (°F)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

backing pump min speed0880 m3/h (0518 cfm)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

Read on drypump-leybold-ruvac-whu.

differential pressure max30 to 45 mbardrypump-leybold-ruvac

Read on drypump-leybold-ruvac.

inlet flange250 ISO-Kdrypump-leybold-ruvac-whu

Read on drypump-leybold-ruvac-whu.

mass590 (1301) kg (lbs)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

noise level< 63 dB(A)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

pumping speed nominal4400 (2592) m3 x h-1 (cfm)drypump-leybold-ruvac

Read on drypump-leybold-ruvac. Served to the builder as 1222 l/s, read from 4400 m3 x h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

service intervalOil change for LVO 210 1 yeardrypump-leybold-ruvac-whu

Read on drypump-leybold-ruvac-whu.

RUVAC WHU 44001222 l/sNominal displacement speeddrypump-leybold-ruvac+9 parameters

Leybold, roots booster.

ambient temp range+12 to +40 (+54 to +104) °C (°F)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

backing pump min speed0880 m3/h (0518 cfm)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

Read on drypump-leybold-ruvac-whu.

differential pressure max90 mbardrypump-leybold-ruvac-whu

Read on drypump-leybold-ruvac-whu.

inlet flange250 ISO-Kdrypump-leybold-ruvac-whu

Read on drypump-leybold-ruvac-whu.

mass590 (1301) kg (lbs)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

noise level< 63 dB(A)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

pumping speed nominal4400 (2592) m3 x h-1 (cfm)drypump-leybold-ruvac

Read on drypump-leybold-ruvac. Served to the builder as 1222 l/s, read from 4400 m3 x h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

service intervalOil change for LVO 210 1 yeardrypump-leybold-ruvac-whu

Read on drypump-leybold-ruvac-whu.

RUVAC RA 30011083 l/sNominal displacement speed, down to 4.0e-2 mbardrypump-leybold-ruvac-ra+10 parameters

Leybold, roots booster.

ambient temp range12 - 40 °Cdrypump-leybold-ruvac-ra

Read on drypump-leybold-ruvac-ra.

backing pump min speed0650 m3/h (0383 cfm)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

differential pressure max53 mbardrypump-leybold-ruvac-ra

Read on drypump-leybold-ruvac-ra.

inlet flangeDN 200drypump-leybold-ruvac-ra

Read on drypump-leybold-ruvac-ra.

Read on drypump-leybold-ruvac-ra.

noise level77 dB (A)drypump-leybold-ruvac-ra

Read on drypump-leybold-ruvac-ra.

Read on drypump-leybold-ruvac-ra.

pumping speed nominal3900 m3 · h-1drypump-leybold-ruvac-ra

Read on drypump-leybold-ruvac-ra. Served to the builder as 1083 l/s, read from 3900 m3 · h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

service interval3,000 hours of operationdrypump-leybold-ruvac-ra

Read on drypump-leybold-ruvac-ra.

ultimate pressurestated as a bound< 4 x 10-2 mbardrypump-leybold-ruvac

Read on drypump-leybold-ruvac.

RUVAC WH 2500694 l/sNominal displacement speeddrypump-leybold-ruvac-whu+5 parameters

Leybold, roots booster.

Read on drypump-leybold-ruvac-whu.

differential pressure max50-75 mbardrypump-leybold-ruvac-whu

Read on drypump-leybold-ruvac-whu.

inlet flange250 ISO-Kdrypump-leybold-ruvac-whu

Read on drypump-leybold-ruvac-whu.

pumping speed nominal2500 m3 . h-1drypump-leybold-ruvac-whu

Read on drypump-leybold-ruvac-whu. Served to the builder as 694 l/s, read from 2500 m3 . h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

service intervalOil change for LVO 210 1 yeardrypump-leybold-ruvac-whu

Read on drypump-leybold-ruvac-whu.

RUVAC WHU 2500694 l/sNominal displacement speeddrypump-leybold-ruvac-whu+5 parameters

Leybold, roots booster.

Read on drypump-leybold-ruvac-whu.

differential pressure max90 mbardrypump-leybold-ruvac-whu

Read on drypump-leybold-ruvac-whu.

inlet flange250 ISO-Kdrypump-leybold-ruvac-whu

Read on drypump-leybold-ruvac-whu.

pumping speed nominal2500 m3 . h-1drypump-leybold-ruvac-whu

Read on drypump-leybold-ruvac-whu. Served to the builder as 694 l/s, read from 2500 m3 . h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

service intervalOil change for LVO 210 1 yeardrypump-leybold-ruvac-whu

Read on drypump-leybold-ruvac-whu.

RUVAC WA 2001569 l/sNominal displacement speed, down to 4.0e-2 mbardrypump-leybold-ruvac-wau+11 parameters

Leybold, roots booster.

ambient temp range12 – 40 °Cdrypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

backing pump min speed0410 m3/h (0241 cfm)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

Read on drypump-leybold-ruvac-wau.

differential pressure max50 mbardrypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

inlet flange160 ISO - Kdrypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

Read on drypump-leybold-ruvac-wau.

noise level< 80 dB (A)drypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

Read on drypump-leybold-ruvac-wau.

pumping speed nominal2050 m3 x h-1drypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau. Served to the builder as 569 l/s, read from 2050 m3 x h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

service intervalafter every 3,000 hours of operationdrypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

ultimate pressurestated as a boundrestated in a second unit, 1.333x apart< 4 x 10-2 (< 3 x 10-2) mbar (Torr)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

RUVAC WAU 2001569 l/sNominal displacement speed, down to 4.0e-2 mbardrypump-leybold-ruvac-wau+11 parameters

Leybold, roots booster.

ambient temp range12 – 40 °Cdrypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

backing pump min speed0410 m3/h (0241 cfm)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

Read on drypump-leybold-ruvac-wau.

differential pressure max50 mbardrypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

inlet flange160 ISO - Kdrypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

Read on drypump-leybold-ruvac-wau.

noise level< 80 dB (A)drypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

Read on drypump-leybold-ruvac-wau.

pumping speed nominal2050 m3 x h-1drypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau. Served to the builder as 569 l/s, read from 2050 m3 x h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

service intervalafter every 3,000 hours of operationdrypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

ultimate pressurestated as a boundrestated in a second unit, 1.333x apart< 4 x 10-2 (< 3 x 10-2) mbar (Torr)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

RUVAC WS 2001569 l/sNominal displacement speed, down to 4.0e-2 mbardrypump-leybold-ruvacws+11 parameters

Leybold, roots booster.

ambient temp range12 - 40 °Cdrypump-leybold-ruvacws

Read on drypump-leybold-ruvacws.

backing pump min speed0410 m3/h (0241 cfm)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

bypass valvenodrypump-leybold-ruvac

Read on drypump-leybold-ruvac.

differential pressure max50 mbardrypump-leybold-ruvacws

Read on drypump-leybold-ruvacws.

inlet flange160 ISO - Kdrypump-leybold-ruvacws

Read on drypump-leybold-ruvacws.

Read on drypump-leybold-ruvacws.

noise level< 72 dB (A)drypump-leybold-ruvacws

Read on drypump-leybold-ruvacws.

Read on drypump-leybold-ruvacws.

pumping speed nominal2050 m3 · h-1drypump-leybold-ruvacws

Read on drypump-leybold-ruvacws. Served to the builder as 569 l/s, read from 2050 m3 · h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

service intervalafter every 3,000 hours of operationdrypump-leybold-ruvacws

Read on drypump-leybold-ruvacws.

ultimate pressurestated as a boundrestated in a second unit, 1.333x apart< 4 x 10-2 (< 3 x 10-2) mbar (Torr)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

RUVAC WS 2001 W569 l/sNominal displacement speed, down to 1.0e-3 mbardrypump-leybold-ruvac+8 parameters

Leybold, roots booster.

bypass valvenodrypump-leybold-ruvac

Read on drypump-leybold-ruvac.

differential pressure max50.0 (37.5) mbar (Torr)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

inlet flange160 ISO-Kdrypump-leybold-ruvac

Read on drypump-leybold-ruvac.

Read on drypump-leybold-ruvac.

noise level< 72 dB(A)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

power max7.5 /8.5 kWdrypump-leybold-ruvac

Read on drypump-leybold-ruvac.

pumping speed nominal2050 (1207.5) m3 x h-1 (cfm)drypump-leybold-ruvac

Read on drypump-leybold-ruvac. Served to the builder as 569 l/s, read from 2050 m3 x h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

ultimate pressurestated as a bound< 1 x 10-3 mbardrypump-leybold-ruvac

Read on drypump-leybold-ruvac.

RUVAC WSU 2001569 l/sNominal displacement speed, down to 4.0e-2 mbardrypump-leybold-ruvacws+11 parameters

Leybold, roots booster.

ambient temp range12 - 40 °Cdrypump-leybold-ruvacws

Read on drypump-leybold-ruvacws.

backing pump min speed0410 m3/h (0241 cfm)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

Read on drypump-leybold-ruvacws.

differential pressure max50 mbardrypump-leybold-ruvacws

Read on drypump-leybold-ruvacws.

inlet flange160 ISO - Kdrypump-leybold-ruvacws

Read on drypump-leybold-ruvacws.

Read on drypump-leybold-ruvacws.

noise level< 72 dB (A)drypump-leybold-ruvacws

Read on drypump-leybold-ruvacws.

Read on drypump-leybold-ruvacws.

pumping speed nominal2050 m3 · h-1drypump-leybold-ruvacws

Read on drypump-leybold-ruvacws. Served to the builder as 569 l/s, read from 2050 m3 · h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

service intervalafter every 3,000 hours of operationdrypump-leybold-ruvacws

Read on drypump-leybold-ruvacws.

ultimate pressurestated as a boundrestated in a second unit, 1.333x apart< 4 x 10-2 (< 3 x 10-2) mbar (Torr)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

RUVAC WSU 2001 W569 l/sNominal displacement speed, down to 1.0e-3 mbardrypump-leybold-ruvac+8 parameters

Leybold, roots booster.

bypass valveyesdrypump-leybold-ruvac

Read on drypump-leybold-ruvac.

differential pressure max50.0 (37.5) mbar (Torr)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

inlet flange160 ISO-Kdrypump-leybold-ruvac

Read on drypump-leybold-ruvac.

Read on drypump-leybold-ruvac.

noise level< 72 dB(A)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

power max7.5 /8.5 kWdrypump-leybold-ruvac

Read on drypump-leybold-ruvac.

pumping speed nominal2050 (1207.5) m3 x h-1 (cfm)drypump-leybold-ruvac

Read on drypump-leybold-ruvac. Served to the builder as 569 l/s, read from 2050 m3 x h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

ultimate pressurestated as a bound< 1 x 10-3 mbardrypump-leybold-ruvac

Read on drypump-leybold-ruvac.

RUVAC WA 1001278 l/sNominal displacement speed, down to 4.0e-2 mbardrypump-leybold-ruvac-wau+11 parameters

Leybold, roots booster.

ambient temp range12 – 40 °Cdrypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

backing pump min speed0200 m3/h (0118 cfm)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

Read on drypump-leybold-ruvac-wau.

differential pressure max80 mbardrypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

inlet flange100 ISO - Kdrypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

Read on drypump-leybold-ruvac-wau.

noise level< 75 dB (A)drypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

Read on drypump-leybold-ruvac-wau.

pumping speed nominal1000 m3 x h-1drypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau. Served to the builder as 278 l/s, read from 1000 m3 x h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

service intervalafter every 3,000 hours of operationdrypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

ultimate pressurestated as a boundrestated in a second unit, 1.333x apart< 4 x 10-2 (< 3 x 10-2) mbar (Torr)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

RUVAC WAU 1001278 l/sNominal displacement speed, down to 4.0e-2 mbardrypump-leybold-ruvac-wau+11 parameters

Leybold, roots booster.

ambient temp range12 – 40 °Cdrypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

backing pump min speed0200 m3/h (0118 cfm)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

Read on drypump-leybold-ruvac-wau.

differential pressure max80 mbardrypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

inlet flange100 ISO - Kdrypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

Read on drypump-leybold-ruvac-wau.

noise level< 75 dB (A)drypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

Read on drypump-leybold-ruvac-wau.

pumping speed nominal1000 m3 x h-1drypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau. Served to the builder as 278 l/s, read from 1000 m3 x h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

service intervalafter every 3,000 hours of operationdrypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

ultimate pressurestated as a boundrestated in a second unit, 1.333x apart< 4 x 10-2 (< 3 x 10-2) mbar (Torr)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

RUVAC WS 1001278 l/sNominal displacement speed, down to 4.0e-2 mbardrypump-leybold-ruvacws+11 parameters

Leybold, roots booster.

ambient temp range12 - 40 °Cdrypump-leybold-ruvacws

Read on drypump-leybold-ruvacws.

backing pump min speed0200 m3/h (0118 cfm)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

bypass valvenodrypump-leybold-ruvac

Read on drypump-leybold-ruvac.

differential pressure max80 mbardrypump-leybold-ruvacws

Read on drypump-leybold-ruvacws.

inlet flange100 ISO - Kdrypump-leybold-ruvacws

Read on drypump-leybold-ruvacws.

Read on drypump-leybold-ruvacws.

noise level< 68 dB (A)drypump-leybold-ruvacws

Read on drypump-leybold-ruvacws.

Read on drypump-leybold-ruvacws.

pumping speed nominal1000 m3 · h-1drypump-leybold-ruvacws

Read on drypump-leybold-ruvacws. Served to the builder as 278 l/s, read from 1000 m3 · h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

service intervalafter every 3,000 hours of operationdrypump-leybold-ruvacws

Read on drypump-leybold-ruvacws.

ultimate pressurestated as a boundrestated in a second unit, 1.333x apart< 4 x 10-2 (< 3 x 10-2) mbar (Torr)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

RUVAC WS 1001 W278 l/sNominal displacement speed, down to 1.0e-3 mbardrypump-leybold-ruvac+8 parameters

Leybold, roots booster.

bypass valvenodrypump-leybold-ruvac

Read on drypump-leybold-ruvac.

differential pressure max80.0 (60.0) mbar (Torr)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

inlet flange100 ISO-Kdrypump-leybold-ruvac

Read on drypump-leybold-ruvac.

Read on drypump-leybold-ruvac.

noise level< 68 dB(A)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

power max4.0/4.4 kWdrypump-leybold-ruvac

Read on drypump-leybold-ruvac.

pumping speed nominal1000 (589) m3 x h-1 (cfm)drypump-leybold-ruvac

Read on drypump-leybold-ruvac. Served to the builder as 278 l/s, read from 1000 m3 x h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

ultimate pressurestated as a bound< 1 x 10-3 mbardrypump-leybold-ruvac

Read on drypump-leybold-ruvac.

RUVAC WSLF 1001278 l/sNominal displacement speeddrypump-leybold-ruvac+5 parameters

Leybold, roots booster.

differential pressure max80 (60) mbar (Torr)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

inlet flangeDN 100drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

mass275 (606.4) kg (lbs)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

power max7.5 (10.2) kW (hp)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

pumping speed nominal1000 (589) m3 x h-1 (cfm)drypump-leybold-ruvac

Read on drypump-leybold-ruvac. Served to the builder as 278 l/s, read from 1000 m3 x h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

RUVAC WSU 1001278 l/sNominal displacement speed, down to 4.0e-2 mbardrypump-leybold-ruvacws+11 parameters

Leybold, roots booster.

ambient temp range12 - 40 °Cdrypump-leybold-ruvacws

Read on drypump-leybold-ruvacws.

backing pump min speed0200 m3/h (0118 cfm)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

Read on drypump-leybold-ruvacws.

differential pressure max80 mbardrypump-leybold-ruvacws

Read on drypump-leybold-ruvacws.

inlet flange100 ISO - Kdrypump-leybold-ruvacws

Read on drypump-leybold-ruvacws.

Read on drypump-leybold-ruvacws.

noise level< 68 dB (A)drypump-leybold-ruvacws

Read on drypump-leybold-ruvacws.

Read on drypump-leybold-ruvacws.

pumping speed nominal1000 m3 · h-1drypump-leybold-ruvacws

Read on drypump-leybold-ruvacws. Served to the builder as 278 l/s, read from 1000 m3 · h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

service intervalafter every 3,000 hours of operationdrypump-leybold-ruvacws

Read on drypump-leybold-ruvacws.

ultimate pressurestated as a boundrestated in a second unit, 1.333x apart< 4 x 10-2 (< 3 x 10-2) mbar (Torr)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

RUVAC WSU 1001 W278 l/sNominal displacement speed, down to 1.0e-3 mbardrypump-leybold-ruvac+8 parameters

Leybold, roots booster.

bypass valveyesdrypump-leybold-ruvac

Read on drypump-leybold-ruvac.

differential pressure max80.0 (60.0) mbar (Torr)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

inlet flange100 ISO-Kdrypump-leybold-ruvac

Read on drypump-leybold-ruvac.

Read on drypump-leybold-ruvac.

noise level< 68 dB(A)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

power max4.0/4.4 kWdrypump-leybold-ruvac

Read on drypump-leybold-ruvac.

pumping speed nominal1000 (589) m3 x h-1 (cfm)drypump-leybold-ruvac

Read on drypump-leybold-ruvac. Served to the builder as 278 l/s, read from 1000 m3 x h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

ultimate pressurestated as a bound< 1 x 10-3 mbardrypump-leybold-ruvac

Read on drypump-leybold-ruvac.

RUVAC WH 700197 l/sNominal displacement speeddrypump-leybold-ruvac+8 parameters

Leybold, roots booster.

ambient temp range+12 to +45 °Cdrypump-leybold-ruvac

Read on drypump-leybold-ruvac.

backing pump min speed0140 m3/h (0082 cfm)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

differential pressure max75.0 mbardrypump-leybold-ruvac

Read on drypump-leybold-ruvac.

inlet flange100 ISO-Kdrypump-leybold-ruvac

Read on drypump-leybold-ruvac.

mass125 (276) kg (lbs)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

noise level< 65 dB(A)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

pumping speed nominal710 (418) m3 x h-1 (cfm)drypump-leybold-ruvac

Read on drypump-leybold-ruvac. Served to the builder as 197 l/s, read from 710 m3 x h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

ultimate pressure< 4-2 (< 3-2) mbar (Torr)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

RUVAC WA 501140 l/sNominal displacement speed, down to 4.0e-2 mbardrypump-leybold-ruvac-wau+11 parameters

Leybold, roots booster.

ambient temp range12 – 40 °Cdrypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

backing pump min speed0100 m3/h (0059 cfm)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

Read on drypump-leybold-ruvac-wau.

differential pressure max80 mbardrypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

inlet flange63 ISO - Kdrypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

Read on drypump-leybold-ruvac-wau.

noise level< 67 dB (A)drypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

Read on drypump-leybold-ruvac-wau.

pumping speed nominal505 m3 x h-1drypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau. Served to the builder as 140 l/s, read from 505 m3 x h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

service intervalafter every 3,000 hours of operationdrypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

ultimate pressurestated as a boundrestated in a second unit, 1.333x apart< 4 x 10-2 (< 3 x 10-2) mbar (Torr)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

RUVAC WAU 501140 l/sNominal displacement speed, down to 4.0e-2 mbardrypump-leybold-ruvac-wau+11 parameters

Leybold, roots booster.

ambient temp range12 – 40 °Cdrypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

backing pump min speed0100 m3/h (0059 cfm)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

Read on drypump-leybold-ruvac-wau.

differential pressure max80 mbardrypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

inlet flange63 ISO - Kdrypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

Read on drypump-leybold-ruvac-wau.

noise level< 67 dB (A)drypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

Read on drypump-leybold-ruvac-wau.

pumping speed nominal505 m3 x h-1drypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau. Served to the builder as 140 l/s, read from 505 m3 x h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

service intervalafter every 3,000 hours of operationdrypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

ultimate pressurestated as a boundrestated in a second unit, 1.333x apart< 4 x 10-2 (< 3 x 10-2) mbar (Torr)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

RUVAC WS 501140 l/sNominal displacement speed, down to 4.0e-2 mbardrypump-leybold-ruvacws+11 parameters

Leybold, roots booster.

ambient temp range12 - 40 °Cdrypump-leybold-ruvacws

Read on drypump-leybold-ruvacws.

backing pump min speed0100 m3/h (0059 cfm)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

bypass valvenodrypump-leybold-ruvac

Read on drypump-leybold-ruvac.

differential pressure max80 mbardrypump-leybold-ruvacws

Read on drypump-leybold-ruvacws.

inlet flange63 ISO - Kdrypump-leybold-ruvacws

Read on drypump-leybold-ruvacws.

Read on drypump-leybold-ruvacws.

noise level< 63 dB (A)drypump-leybold-ruvacws

Read on drypump-leybold-ruvacws.

Read on drypump-leybold-ruvacws.

pumping speed nominal505 m3 · h-1drypump-leybold-ruvacws

Read on drypump-leybold-ruvacws. Served to the builder as 140 l/s, read from 505 m3 · h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

service intervalafter every 3,000 hours of operationdrypump-leybold-ruvacws

Read on drypump-leybold-ruvacws.

ultimate pressurestated as a boundrestated in a second unit, 1.333x apart< 4 x 10-2 (< 3 x 10-2) mbar (Torr)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

RUVAC WS 501 W140 l/sNominal displacement speed, down to 4.0e-2 mbardrypump-leybold-ruvac+8 parameters

Leybold, roots booster.

bypass valvenodrypump-leybold-ruvac

Read on drypump-leybold-ruvac.

differential pressure max80 (60) mbar (Torr)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

inlet flange63 ISO-Kdrypump-leybold-ruvac

Read on drypump-leybold-ruvac.

mass130.0 (286.7) kg (lbs)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

noise level< 63 dB(A)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

power max2.2 (3.0)/2.4 (3.3) kW (hp)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

pumping speed nominal505.0 (297.4) m3 x h-1 (cfm)drypump-leybold-ruvac

Read on drypump-leybold-ruvac. Served to the builder as 140 l/s, read from 505 m3 x h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

ultimate pressurestated as a boundrestated in a second unit, 1.333x apart< 4 x 10-2 (< 3 x 10-2) mbar (Torr)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

RUVAC WSU 501140 l/sNominal displacement speed, down to 4.0e-2 mbardrypump-leybold-ruvacws+11 parameters

Leybold, roots booster.

ambient temp range12 - 40 °Cdrypump-leybold-ruvacws

Read on drypump-leybold-ruvacws.

backing pump min speed0100 m3/h (0059 cfm)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

Read on drypump-leybold-ruvacws.

differential pressure max80 mbardrypump-leybold-ruvacws

Read on drypump-leybold-ruvacws.

inlet flange63 ISO - Kdrypump-leybold-ruvacws

Read on drypump-leybold-ruvacws.

Read on drypump-leybold-ruvacws.

noise level< 63 dB (A)drypump-leybold-ruvacws

Read on drypump-leybold-ruvacws.

Read on drypump-leybold-ruvacws.

pumping speed nominal505 m3 · h-1drypump-leybold-ruvacws

Read on drypump-leybold-ruvacws. Served to the builder as 140 l/s, read from 505 m3 · h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

service intervalafter every 3,000 hours of operationdrypump-leybold-ruvacws

Read on drypump-leybold-ruvacws.

ultimate pressurestated as a boundrestated in a second unit, 1.333x apart< 4 x 10-2 (< 3 x 10-2) mbar (Torr)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

RUVAC WA 25170.3 l/sNominal displacement speed, down to 8.0e-4 mbardrypump-leybold-ruvac-wau+11 parameters

Leybold, roots booster.

ambient temp range12 – 40 °Cdrypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

backing pump min speed0050 m3/h (0029 cfm)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

Read on drypump-leybold-ruvac-wau.

differential pressure max80 mbardrypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

inlet flange63 ISO - Kdrypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

Read on drypump-leybold-ruvac-wau.

noise level< 64 dB (A)drypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

Read on drypump-leybold-ruvac-wau.

pumping speed nominal253 m3 x h-1drypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau. Served to the builder as 70.3 l/s, read from 253 m3 x h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

service intervalafter every 3,000 hours of operationdrypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

ultimate pressurestated as a boundrestated in a second unit, 1.333x apart< 8 x 10-4 (< 6 x 10-4) mbar (Torr)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

RUVAC WAU 25170.3 l/sNominal displacement speed, down to 8.0e-4 mbardrypump-leybold-ruvac-wau+11 parameters

Leybold, roots booster.

ambient temp range12 – 40 °Cdrypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

backing pump min speed0050 m3/h (0029 cfm)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

Read on drypump-leybold-ruvac-wau.

differential pressure max80 mbardrypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

inlet flange63 ISO - Kdrypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

Read on drypump-leybold-ruvac-wau.

noise level< 64 dB (A)drypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

Read on drypump-leybold-ruvac-wau.

pumping speed nominal253 m3 x h-1drypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau. Served to the builder as 70.3 l/s, read from 253 m3 x h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

service intervalafter every 3,000 hours of operationdrypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

ultimate pressurestated as a boundrestated in a second unit, 1.333x apart< 8 x 10-4 (< 6 x 10-4) mbar (Torr)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

RUVAC WS 25170.3 l/sNominal displacement speed, down to 8.0e-4 mbardrypump-leybold-ruvacws+11 parameters

Leybold, roots booster.

ambient temp range12 - 40 °Cdrypump-leybold-ruvacws

Read on drypump-leybold-ruvacws.

backing pump min speed0050 m3/h (0029 cfm)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

bypass valvenodrypump-leybold-ruvac

Read on drypump-leybold-ruvac.

differential pressure max80 mbardrypump-leybold-ruvacws

Read on drypump-leybold-ruvacws.

inlet flange63 ISO - Kdrypump-leybold-ruvacws

Read on drypump-leybold-ruvacws.

Read on drypump-leybold-ruvacws.

noise level< 63 dB (A)drypump-leybold-ruvacws

Read on drypump-leybold-ruvacws.

Read on drypump-leybold-ruvacws.

pumping speed nominal253 m3 · h-1drypump-leybold-ruvacws

Read on drypump-leybold-ruvacws. Served to the builder as 70.3 l/s, read from 253 m3 · h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

service intervalafter every 3,000 hours of operationdrypump-leybold-ruvacws

Read on drypump-leybold-ruvacws.

ultimate pressurestated as a boundrestated in a second unit, 1.333x apart< 8 x 10-4 (< 6 x 10-4) mbar (Torr)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

RUVAC WSU 25170.3 l/sNominal displacement speed, down to 8.0e-4 mbardrypump-leybold-ruvacws+11 parameters

Leybold, roots booster.

ambient temp range12 - 40 °Cdrypump-leybold-ruvacws

Read on drypump-leybold-ruvacws.

backing pump min speed0050 m3/h (0029 cfm)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

Read on drypump-leybold-ruvacws.

differential pressure max80 mbardrypump-leybold-ruvacws

Read on drypump-leybold-ruvacws.

inlet flange63 ISO - Kdrypump-leybold-ruvacws

Read on drypump-leybold-ruvacws.

Read on drypump-leybold-ruvacws.

noise level< 63 dB (A)drypump-leybold-ruvacws

Read on drypump-leybold-ruvacws.

Read on drypump-leybold-ruvacws.

pumping speed nominal253 m3 · h-1drypump-leybold-ruvacws

Read on drypump-leybold-ruvacws. Served to the builder as 70.3 l/s, read from 253 m3 · h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

service intervalafter every 3,000 hours of operationdrypump-leybold-ruvacws

Read on drypump-leybold-ruvacws.

ultimate pressurestated as a boundrestated in a second unit, 1.333x apart< 8 x 10-4 (< 6 x 10-4) mbar (Torr)drypump-leybold-ruvac

Read on drypump-leybold-ruvac.

RUVAC WA 15142.5 l/sNominal displacement speeddrypump-leybold-ruvac-wau+9 parameters

Leybold, roots booster.

ambient temp range12 – 40 °Cdrypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

Read on drypump-leybold-ruvac-wau.

differential pressure max130 mbardrypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

inlet flange63 ISO - Kdrypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

Read on drypump-leybold-ruvac-wau.

noise level< 63 dB (A)drypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

Read on drypump-leybold-ruvac-wau.

pumping speed nominal153 m3 x h-1drypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau. Served to the builder as 42.5 l/s, read from 153 m3 x h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

service intervalafter every 3,000 hours of operationdrypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

RUVAC WAU 15142.5 l/sNominal displacement speeddrypump-leybold-ruvac-wau+9 parameters

Leybold, roots booster.

ambient temp range12 – 40 °Cdrypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

Read on drypump-leybold-ruvac-wau.

differential pressure max130 mbardrypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

inlet flange63 ISO - Kdrypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

Read on drypump-leybold-ruvac-wau.

noise level< 63 dB (A)drypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

Read on drypump-leybold-ruvac-wau.

pumping speed nominal153 m3 x h-1drypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau. Served to the builder as 42.5 l/s, read from 153 m3 x h-1. Export rule: published nominal displacement speed, species not stated by the manufacturer, single published value, no regime to choose. Conversion: m3/h to l/s, exact factor 1/3.6.

service intervalafter every 3,000 hours of operationdrypump-leybold-ruvac-wau

Read on drypump-leybold-ruvac-wau.

QMB1200Fno pumping speed published under any keydown to 8.0e-4 mbar+6 parameters

Edwards, roots booster.

ambient temp range5 to 40 oCdrypump-edwards-qmb

Read on drypump-edwards-qmb.

differential pressure max0 to 90 mbardrypump-edwards-qmb

Read on drypump-edwards-qmb.

inlet flangeISO160 bolteddrypump-edwards-qmb

Read on drypump-edwards-qmb.

Read on drypump-edwards-qmb.

noise level70 dB(A)drypump-edwards-qmb

Read on drypump-edwards-qmb.

ultimate pressure8 x 10-4 mbardrypump-edwards-qmb

Read on drypump-edwards-qmb.

QMB250Fno pumping speed published under any keydown to 8.0e-4 mbar+6 parameters

Edwards, roots booster.

ambient temp range5 to 40 oCdrypump-edwards-qmb

Read on drypump-edwards-qmb.

differential pressure max0 to 180 mbardrypump-edwards-qmb

Read on drypump-edwards-qmb.

inlet flangeISO63 bolteddrypump-edwards-qmb

Read on drypump-edwards-qmb.

Read on drypump-edwards-qmb.

noise level66 dB(A)drypump-edwards-qmb

Read on drypump-edwards-qmb.

ultimate pressure8 x 10-4 mbardrypump-edwards-qmb

Read on drypump-edwards-qmb.

QMB500Fno pumping speed published under any keydown to 8.0e-4 mbar+6 parameters

Edwards, roots booster.

ambient temp range5 to 40 oCdrypump-edwards-qmb

Read on drypump-edwards-qmb.

differential pressure max0 to 110 mbardrypump-edwards-qmb

Read on drypump-edwards-qmb.

inlet flangeISO100 bolteddrypump-edwards-qmb

Read on drypump-edwards-qmb.

Read on drypump-edwards-qmb.

noise level66 dB(A)drypump-edwards-qmb

Read on drypump-edwards-qmb.

ultimate pressure8 x 10-4 mbardrypump-edwards-qmb

Read on drypump-edwards-qmb.

11 models the base carries no speed and no ultimate for

They are in the corpus and they are named here. What is missing is a published value to judge them on, which is not the same as a model that fails.

  • 607 Edwards 5 parameters
  • 615 Edwards 6 parameters
  • 622 Edwards 5 parameters
  • EH1200 Edwards 8 parameters
  • EH250 Edwards 8 parameters
  • EH2600 Edwards 8 parameters
  • EH2600FX Edwards 6 parameters
  • EH4200 Edwards 8 parameters
  • EH4200FX Edwards 6 parameters
  • EH500 Edwards 8 parameters
  • RUVAC WH 702 Leybold 2 parameters
The 8 documents this family reads
  1. drypump-edwards-booster S900-01-880 Issue C Original Instruction Manual 6 Inch MSeal Booster Pumps and Process Isolation Booster Pumps We, Edwards, Manor Royal, Edwards https://www.ptb-sales.com/manuals/edwards/booster.pdf
  2. drypump-edwards-eh A301-05-880 Issue A Original Instructions Instruction Manual EH Mechanical Booster Pumps For safe area applications We, Edwards Limited, Edwards https://www.ptb-sales.com/manuals/edwards/eh.pdf
  3. drypump-edwards-qmb A301-85-880 Issue M Instruction Manual QMB Mechanical Booster Pumps QMB250F Mechanical Booster Pump, 50Hz A301-85-905 QMB250F Mechanical Booster Pump, 60 Hz A301-86-905 Edwards https://www.ptb-sales.com/manuals/edwards/qmb.pdf
  4. drypump-leybold-ruvac RUVAC Roots Vacuum Pumps Single-Stage 250 - 13 000 m3 x h-1 (147 - 7657 cfm) 173.01.02 Excerpt from the Oerlikon Leybold Vacuum Full Line Catalog Leybold https://www.ptb-sales.com/manuals/leybold/ruvac.pdf
  5. drypump-leybold-ruvac-ra Vacuum Solutions Application Support Service LEYBOLD VACUUM GA 03.201/5.02 RUVAC RA Roots Pumps RA 3001, 5001, 7001, 9001, 13000 Cat. No. Leybold https://www.ptb-sales.com/manuals/leybold/ruvac-ra.pdf
  6. drypump-leybold-ruvac-wau Vacuum Pumps Instrumentation Fittings and Valves LEYBOLD VACUUM GA 03.107/10.02 RUVAC WA/WAU 151/251/501/1001/2001 Cat. No. 117 10/20/30/40/50 Leybold https://www.ptb-sales.com/manuals/leybold/ruvac-wau.pdf
  7. drypump-leybold-ruvac-whu RUVAC WH / WHU 2500 / 4400 / 7000 Roots booster with synthetic oil or PFPE-filling Installation and Operating Instructions 130001398_002_C0 Leybold https://www.ptb-sales.com/manuals/leybold/ruvac-whu.pdf
  8. drypump-leybold-ruvacws Vacuum Solutions Application Support Service LEYBOLD VACUUM GA 03.108/14.02 RUVAC WS/WSU 251/501/1001/2001 Roots pump with mineral oil, Leybold https://www.ptb-sales.com/manuals/leybold/ruvacws.pdf